+91-8755475716 WhatsApp Us Send EnquiryAgra isn't an electronics manufacturing city, so antistatic flooring here is mostly about protecting expensive equipment rather than production lines. We see demand from hospitals building operation theatres and imaging suites, hotels and banks with server rooms, and service centres that repair phones, computers and medical devices. For these rooms, a small investment in the right floor protects equipment worth far more.
Agra's hospital sector is expanding, with new OT complexes, cath labs and imaging centres. Floors in these rooms usually need to meet a hospital specification that includes:
We lay these floors over a copper grid with a conductive primer, finish with an antistatic self levelling epoxy or PU, and test resistance before handover.
Server rooms in hotels, banks and offices are often small rooms that were never designed for IT equipment. They frequently have ordinary tiles or bare concrete, and static builds up when staff walk in during dry winter months. Replacing or coating the floor with an antistatic system is a straightforward fix, and it can usually be done in a day or two with careful protection of running equipment.
Phone, laptop and medical device repair centres open up electronics every day. A technician's footsteps on a tiled floor can build enough charge to damage a board. An ESD floor in the repair area, used with ESD footwear and bench mats, reduces repeat failures and warranty returns.
Agra's summer heat and dust affect resin work. Hot slabs speed up curing and make self levelling finishes harder to get right, while dust settling on a fresh floor spoils the finish. In summer we work early in the day, cool the room where possible and keep it sealed until the surface has set.
The floor doesn't need special care, but a few habits matter. Clean with a neutral cleaner, never wax or polish, use ESD-safe mats rather than rubber ones, and ask staff in sensitive rooms to wear ESD footwear. Retest the floor periodically, and always after any repair.
A small server room can often be completed in a few days including curing and testing. We protect running equipment during the work.
If the tiles are sound and well bonded, yes, after grinding. Loose tiles must be removed first.
It depends on the hospital's specification and the equipment used. Your project or biomedical engineer should confirm the requirement.
Call +91-8755475716 or fill in the form below to discuss your room in Agra. More details are on our antistatic ESD flooring page.