+91-8755475716 WhatsApp Us Send EnquiryKanpur has a long association with defence manufacturing, and a network of suppliers has grown around it. Some of these units handle propellants, pyrotechnics or other materials where a static spark is a safety hazard. The city also has electrical manufacturers, research institutions and a large hospital sector. Each needs static control for a different reason, and the right floor for one can be wrong for another.
Where explosives, propellants, pyrotechnic compositions or flammable solvent vapours are present, static discharge from a person or trolley can cause ignition. These areas typically use conductive flooring with a low resistance to earth, combined with conductive footwear, so charge drains away almost immediately.
Requirements in these facilities are set by the relevant safety regulations and the facility's own hazard assessment. We don't guess the specification. We ask for the required resistance range and any other conditions, such as a spark-free floor surface, and build and test to match.
A few practical points about these floors:
Kanpur's electrical goods and electronics units need static dissipative floors in areas where boards and components are handled. These floors have a higher resistance range, usually 10⁶ to 10⁹ ohms, designed to protect electronics rather than prevent ignition. Using a conductive floor in an electronics room isn't automatically better. It can be the wrong specification, so the distinction matters.
University and institute labs working with electronics, materials or instrumentation use ESD floors at their benches and instrument areas. We plan these jobs around academic calendars.
Operation theatres and ICUs in Kanpur's hospitals often have specifications calling for antistatic floors, along with jointless coved finishes for infection control.
The layers are similar for conductive and dissipative floors, but the materials and target resistance differ:
Areas with explosives or flammable vapours usually require conductive flooring. The exact range must come from your facility's regulations and hazard assessment.
Yes. We test resistance at handover and give you the readings. Regular retesting should be part of your facility's safety procedures.
Yes. Conductive or ESD footwear is essential. Without it, the floor can't drain charge from people.
Call +91-8755475716 or fill in the form below to discuss your requirements in Kanpur. More details are on our antistatic ESD flooring page.
Share a few details and our team will call you back within 24 hours. Prefer to talk now? Call +91-8755475716.