+91-8755475716 WhatsApp Us Send EnquiryAs the state capital, Lucknow has large government and private data centres, along with network operations rooms for banks and telecom companies. It is also home to aerospace and defence electronics work, national research laboratories and some of the biggest hospitals in north India. Static control matters in all of them. We build antistatic and ESD floors that are earthed, tested and suited to how each room is actually used.
Most data halls use raised access floors, and the panels usually come with their own static-control finish. Problems often start underneath:
We seal the sub-floor with an antistatic coating that stops dusting. UPS rooms, battery rooms, network rooms and staging areas without raised floors can take a full ESD floor. Work is scheduled in coordination with your change windows and protected from running equipment.
Units making or supporting avionics and defence electronics usually work to formal ESD control programmes. Their floors are specified to a resistance range, installed as part of a documented ESD protected area and tested regularly. We build to the specification, provide test readings at handover and can repair and retest sections later without disturbing the rest.
Research labs in Lucknow handle sensitive instruments, electronics and sometimes flammable solvents. Depending on the room, the need might be static dissipative flooring for instruments or conductive flooring where solvent vapours are present. We look at each room separately.
Operation theatres, ICUs and cath labs in Lucknow's large hospitals often call for antistatic floors. These are built as jointless self levelling floors with coved skirting, so they meet both the static and infection control requirements.
| Stage | Details |
|---|---|
| Survey | Resistance requirement, room use, slab condition |
| Preparation | Grinding, repairs, levelling |
| Conductive layers | Copper grid, earthing points, conductive primer |
| Finish | ESD or antistatic epoxy or PU, coves where needed |
| Earthing | Connection to building earth by your electrician |
| Testing | Resistance readings at multiple points |
Having these answers makes the quote accurate and avoids a floor that doesn't meet your requirement.
Yes, in most cases. Sealing it stops concrete dust from entering the cooling airflow and adds static control underneath the raised floor.
Yes, with careful dust control and protection. We plan the sequence with your facility team.
Yes. We give you resistance readings and test locations at handover for your records.